Chamber water volume
|
50 liter
|
Chamber working pressure
|
1 to 60 psia with 14.7 psia ambient
|
Acclimation pressure range
|
20 to 60 psia with 14.7 psia ambient
|
Acclimation pressure control
|
+1 psi
|
Acclimation press/depress rate
|
Up to 60 psi/min
|
Spike pressure range
|
1 to 60 psia with 14.7 psia ambient
|
Spike press/depress rate
|
1 to 300 psi/sec
|
Access port opening
|
12-inch diameter.
|
Acclimation water flow range
|
1 to 5 gpm (less at 5 psig or less)
|
Water flow accuracy
|
+0.5 gpm
|
Air pocket control
|
Automatic control
|
Viewing Features
|
4 sided flat lens for minimum optical distortion
|
Fish removal system
|
4" diameter lower drain. Manual operated full port ball valve
|
Spare ports
|
2 each 1/2" NPT ports
|
Water temperature range
|
5 to 30 degrees Celcius
|
Pressure sensing accuracy
|
+0.2 psi
|
Computer control software
|
National Instruments Labview
|
Standby Computer
|
Identical hardware as Primary
|
Pumping System
|
2 pumps of 3/4 hp each supplied by a water tower system to maintain a steady suction head.
|
Compressed Air System
|
1 air compressor of 3/4 hp. 2.5 cfm @ 100 psi
|