For performance testing of personal breathing apparatus
Reimers Systems, Inc. has been a producer of quality breathing simulators and life support equipment for over 20 years. RSI's Personal Breathing Apparatus Test Station (PBATS) represents a masterful integration of that experience with easy-to-use, state-of-the-art technology. The PBATS is designed to accurately test and document the performance of a wide variety of breathing apparatus, such as those used for: DIVING, FIREFIGHTING, MINE RESCUE, AEROSPACE and more.
General Features:
- State-of-the-art technology, laboratory accuracy.
- Compact and portable.
- Fully functional and ready to go to work.
- Versatile and upgradeable.
- Simple and robust design.
Reimers Systems, Inc. All Rights Reserved 2011.
RSI Products > PERSONAL BREATHING APPARATUS TEST STATION
Lung Module:
- Computer controlled: Waveforms are initially provided for ventilation rates of 15, 22.5, 40, 62.5, 75 and 90 liters per minute with industry standard tidal volumes and a sinusoidal pattern. These waveforms can be easily added to or modified.
- Extremely accurate, even with heavy breathing resistance.
- Versatile: can produce any physiologically reasonable waveform. Can be placed within a pressure vessel while the control module remains outside (optional wire feedthru kit is available).
- Smooth waveform generation, even at low RMV's, by use of a zero-backlash ball screw & servo motor drive. None of the roughness in motion associated with stepper motor drives.
- Easy to use and maintain: design is elegantly simple and thus reduces potential testing anomalies.
- Overload protection in the event of gas port blockage.
- Device leakage protection: breathing circuit collects and allows for on-line draining of water (for wet testing applications). Tests do not have to be aborted due to nuisance leaks.
- Instrumented: includes respired volume and pressure transducer.
Data Acquisition and Control Module:
- Personal Computer: Latest standard PC included or customer can provide one for credit.
- Data Acquisition Board: 8 analog input channels. 110 or 220 VAC power user specified.
- Servo control system: digital motion controller and power supplies.
Software:
- Motion control is provided by a versatile and general servo control program that provides a broad range of control options or can be modified as necessary using a simple control language.
- An Excel spreadsheet is provided that calculates work of breathing and peak respiratory pressures for the device being tested. This program also prepares the data for printing.
- A commercial data acquisition program is also provided for setting up test protocols and handling test data received thru the data acquisition board.
- All data acquisition and manipulation processes have been developed and proven in Reimers' own pressure test lab under rigorous project conditions.
Other:
- High quality calibration pump and manometer for pressure transducer calibration.
- Comes secured within rugged, re-usable containers for shipping.
Options:
- Wire feed thru kit (for using the Lung Module within a pressure or altitude chamber)
- Water Test Tank
- Temperature and Humidity Control
- C02 add System
- Larger tidal volumes
- Manikin head